Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises

Product Details
Customization: Available
Type: High-voltage
Structure: Three-column Disconnector
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (13)
  • Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
  • Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
  • Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
  • Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
  • Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
  • Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
Find Similar Products
  • Overview
  • Product Description
  • Model and Meaning
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Packaging & Shipping
  • Our Advantages
Overview

Basic Info.

Model NO.
unspecified
Installation
Indoor High-voltage
Operation
Manual Electric
Grounding Mode
Grounding
Movement Mode
Horizontal Rotary Type
Number of Poles
Three Pole
Grounding
Contact Us
Series
Three
Run
Swing
Switching Mode
Double-Throw Type
Common Model
Fkn1
Structure of Operating
Electric
Certification
ISO, GS, RoHS, CE, IS9001, ISO9001, ISO9002, ISO2000
Brand
Mingzhe
Rated Voltage
12kv
Rated Frequency
50Hz
Rated Dynamic Current
50kv
Characterization
Rapid Disconnection
Transport Package
Pallet Wooden
Specification
Please contact the merchant for detailed specifica
Trademark
MINGZHE
Origin
China

Product Description


 
Product Description
 

Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises

Product Description:

  FZN21-12D/T630-20, FZRN21-12D/T125-31.5 type indoor high-voltage vacuum load switch and combination of electrical appliances for three-phase AC 50Hz power distribution system, has a compact structure, small size, light weight, long service life, with the advantages of strong closing and opening capacity, safe and reliable, etc., and fuse with the use of (referred to as combination of electrical appliances), can replace the more expensive circuit breaker, and easy to operate and maintain. It can be used together with fuse (referred to as combined electric appliance) to replace the circuit breaker which is more expensive, and it is simple and convenient to operate and maintain. 

 
Model and Meaning

Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises
Product Parameters
NO. Items Unit Data
      FKN12-12D/630 FKN12-12(R)D/630
1 Rated voltage KV 12
2 Rated frequency Hz 50
3 Rated Current A 630 1250
4 Lightning impulse withstand voltage KV To earth and phase to phase 75, isolation fracture 85
5 1 min power frequency withstand voltage KA To earth and phase to phase 42, isolation fracture 48
6 Rated thermal stability current KA 20(4s)
7 Rated dynamic current KA 50
8 Rated dosing current (peak) KA 50 50
9 Rated short circuit breaking current (Expected value) KA   31.5
10 Maximum at critical breaking current A2S According to the fuse characteristic curve
11 Minimum breaking current KA According to the fuse characteristic curve
12 Rated transfer current KA   1.5
13 Maximum breaking current (reference value) KA 1.8
14 Breaking the capacity of the no-load transformer KVA 1250
15 Rated cable charging current A 10
16 Rated active load current breaking times Times >100
17 The impactor touches the load switch opening time S   >0.06
18 Earthing switch thermal stability current KA 20(2S)
19 Earthing switch thermal stability current (peak) KA 50
20 Motor operating power supply voltage V AC DC 110, 220


 
No. Name Unit Data
1 Fracture from mm >175
 
2 Phase center distance mm 210±2
 
3 Interphase air gap mm > 125
 
4 Trip mm 210
5 Over Trip mm >40
 
6 Three-phase closing is not the same period ms <10
 
7 Three-phase opening is not the same period ms <5
 
8 The inherent opening time of divider exciter ms 40-65
 
9 Main circuit resistance <300
Detailed Photos

Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial EnterprisesIndoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises

Installation Instructions

Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial EnterprisesIndoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial EnterprisesIndoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises

Packaging & Shipping

Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises

Our Advantages

 

Indoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial EnterprisesIndoor High Voltage Weather Resistance Vacuum Switches for Power Distribution for Industrial Enterprises

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier