ZW7-1600
ZW7-40.5 outdoor high voltage vacuum circuit breaker is used for AC three-phase power system with 50Hz and voltage of 40.5KV, which is used for breaking, closing load current, overload current and short circuit current.
The main function:
1. Vacuum arc extinguishing, strong breaking capacity, long electrical life and 10,000 mechanical life;
2. Simple structure, maintenance-free, long maintenance period;
3. Good insulation performance and strong anti-pollution ability;
4. It can be equipped with spring or electromagnetic operating mechanism, with reliable mechanical performance and frequent operation; no fire and explosion hazard;
5. Built-in current transformer, the lecturer's precision reaches 0.2, which can realize three-phase interactive protection;
6. With condensation controller, it can keep the circuit breaker running reliably under certain temperature and humidity.
Environmental conditions:
1. Ambient air temperature: upper limit +50°C, lower limit -30°C;
2. Altitude: ≤3000m (If the altitude is to be increased, the rated insulation level will increase accordingly);
3. Wind pressure: no more than 700Pa (equivalent to a wind speed of 34m/s);
4. Amplitude: seismic intensity of 8 degrees;
5. Pollution level: Level III;
6. Large daily temperature difference: no more than 35°C.
NO |
Item |
Unit |
Value |
||
1 |
Rated voltage |
KV |
40.5 |
||
2 |
Rated insulation level |
Power frequency withstand voltage |
Dry test |
95 |
|
Wet test |
80 |
||||
Lightning impulse withstand voltage (peak) |
185 |
||||
3 |
Rated current |
A |
1250,1600,2000 |
||
4 |
Rated short-circuit breaking current |
KA |
20,25,31.5 |
||
5 |
Rated operation sequence |
|
0-0.3s-combination-180s-combination |
||
6 |
Rated short circuit current breaking times |
times |
12 |
||
7 |
Rated short circuit closing current (peak) |
KA |
50,63,80 |
||
8 |
Rated peak withstand current |
||||
9 |
Rated short-time withstand current |
KA |
20,25,31.5 |
||
10 |
Rated short circuit continuous current |
S |
4 |
||
11 |
Average opening speed |
m/s |
1.5±0.2 |
||
12 |
Average closing speed |
0.7±0.2 |
|||
13 |
Contact closing bounce time |
s |
≤2 |
||
14 |
Three-phase combined (minute) gate synchronous time difference |
≤2 |
|||
15 |
Closing time |
≤150 |
|||
16 |
Opening time |
≤60 |
|||
17 |
Mechanical life |
times |
10000 |
||
18 |
Rated operating voltage and auxiliary circuit rated voltage |
V |
DC220,110,24 |
||
AC220,110,24 |
|||||
19 |
DC resistance per phase circuit (without transformer) |
μΩ |
≤100 |
||
20 |
Dynamic and static contacts allow wear thickness |
mm |
3 |
||
21 |
weight |
kg |
800 |