• Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
  • Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
  • Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
  • Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
  • Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
  • Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module

Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module

Type: Bearing, High-Voltage
Structure: Three-Column Disconnector
Installation: Outdoor High-Voltage
Grounding Mode: Grounding
Movement Mode: Horizontal Rotary Type
Number of Poles: Three Pole
Samples:
US$ 1500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
Overview

Basic Info.

Model NO.
FLW34-12/630A
Series
Three
Run
Swing
Switching Mode
Double-Throw Type
Structure of Operating
Electric
Certification
ISO, GS, RoHS, CE, Is9001, ISO9001, ISO9002, ISO2000
Operation
Manual Electric
Common Model
Pgs-630A
Brand
Mingzhe
Rated Voltage
12kv 24kv 40.5kv
Rated Current
630A 400A
Switch
Sf6 Pole Mounted Lbs
Withstand Current
25ka
Protecting Type
Conventional Circuit Breaker, Circuit-Breaker Fail
Mechanical Life
10000times
Transport Package
Pallet Wooden
Specification
600x900x2000
Trademark
MINGZHE
Origin
China
HS Code
8535299000
Production Capacity
500PCS/Week

Product Description

Product Description

24kv 36KV /400A-20ka Outdoor Pole Mounted Sf6 Gas Insulated Load Break Switch (LBS)

Summary

Pole-mounted load break switch(pole-LBS) applies up to 36KV 400/630A, 50Hz pole-LBS associated with a state of the art controller. This SF6 gas-insulated switch can corporate with the distribution automation system, and also isolate a faulted section of distribution line from the control center.

A simple pole-mounting arrangement contribute to quick and low cost installation, and the switch can be operated manually with a electronic controller. Electronic controller is contained in a stainless steel cabinet for an all weather environmental conditions. Remote monitoring and control can also be provided mounting wire or wireless modem in a cabinet.

Standard service condition

It shall be principal that this SF6 Gas Load Break Switch shall be used in the following service condition:
Ambient temperature
Short period peak value:50ºC
Average over a period of 24 hours: 40ºC
Lower limit over 24 hours: -25ºC
Relative humidity: 100%
Maximum altitude:1,000 meter

Features
 

  1. rugged switch
  2. drivepipe with large diversity
  3. quick operation
  4. inflation valve
  5. high pressure relief alarm
  6. HD gas-pressure meter
  7. Manual locking device
  8. Low pressure warning device
  9. Visible open/close status
  10. Cintact position indicator
  11. Manual operation on ground
  12. To provide one-stop service, please consult!

 

Detailed Photos
Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module
Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module

 

Product Parameters
Product mode   FLW34-12/630A FLW34-24/630A FLW34-36/630A
Rated voltage KV 12 24 36
6/12/17.5 25.8 36
Rated frequency Hz 50/60 50/60 50/60
Lightning impulse withstand voltage KV 110 125 200
Power frequency withstand voltage 1min Dry KV 50 75 110
wet 40 60 95
Rated current A 400/630
Peak withstand current KA 50 50 50
Rated short time making current KA 20 20 20
Rated short time withstand current KA/S  4./20  4./20  4./20
Rated cable charging breaking current A 10 16 20
Rated line charging breaking current A 1 1.5 2
Rated closed-loop breaking current A 400/630
Rated current breaking times Times ≥400
Rated working pressure Mpa 0.05
Per-phase main circuit resistance ≤80
Relative gas leakage rate Year ≤1%
Operation of mechanical stability Times 6000
weight kg 115 125 135
Institutions boxes and controller protection class IP67
Type of mounting The lifting type(suspended)/block(horizontal)
Packaging & Shipping

Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module

Company Profile

Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module

Our Advantages

Outdoor Load Break Switch /Lbs Breaker/Arrester Protector/Load Break Switch PLC Control CPU Siemens Module

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Import & Export Mode
Exportation Via Agency
Terms of Payment
LC, T/T, D/P, PayPal
International Commercial Terms(Incoterms)
FOB, CIF, CFR