Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Composed of Switch Room, Fuse Room, Operation Mech |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
FL(R)N36-12(D) Load switches and combiners (hereinafter referred to as "load switches" and "combiners") are suitable for three-phase ac power systems of 10kV and 50Hz
This product as industrial and mining enterprises, high-rise buildings, residential quarters, pre-installed type substation, for the breaking, closing load current, the fault current, control and protection circuit and the power distribution transformer
1.normal operating conditions
a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
f) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.
GB 3804-2004 3.6KV~40.5KVHigh voltage ac load switch
GB 16926-2009 High voltage ac load switch fuse combination electrical appliance
GB 11023-1989 Test guide for fln36 gas seal of high pressure switching equipment
GB 1985-2004 High voltage ac isolation switch and ground switch
GB/T 11022-2011 Common technical requirements for high voltage switching equipment and control equipment standards
No. |
|
Unit | Data | ||
FLN36-12 | FLN36-12D | ||||
1 |
|
kV | 12 | ||
2 |
|
A | 630 | 125 | |
3 | Load switch rated short - term withstand current/duration | kA/s | 20/3 | ||
Ground switch rated short - term withstand current/duration | kA/s | 20/2 | |||
4 | Rated peak withstand current and short circuit closing current | kA | 50 | 125(Expect) | |
5 | Rated active load switching current | A | 630 | ||
6 | Rated closed loop breaking current | A | 630 | ||
7 | 5% rated active load open current | A | 31.5 | ||
8 | Rated cable charging current | A | 10 | ||
9 | Rated capacity of open - break no-load transformer | kVA | 1250 | ||
10 | Rated transfer open current | A | 1700 | ||
11 | Rated expected short circuit open current | kA | 50 | ||
12 | Rated insulation level | ||||
1min working frequency withstand voltage phase to ground/break | kV | 42/48 | |||
Lightning shock withstand voltage alternate, ground - to - ground/break | kV | 75/85 | |||
13 |
Mechanical endurance
|
5000 | |||
14 | SF6 pressure rating (20 ºC) | MPa | 0.04 ~0.05 | ||
15 | Rated operating voltage of electric mechanism | V | AC/DC220 | ||
16 | Power frequency withstand voltage of secondary line 1min | V | 2000 | ||
17 | Air leak rate | /Year | <0.5% |
valve | Bosch Rexroth R901252622 |
solenoid valve | Bernstein 6018169054 SLK-F-UC-22-R1-A0-L0-0 |
MOTOR | SITI MOTOR siti mi 90 f b9 nu/28 15/1 |
sensor | TURCK FCS-K20-AP8X |
sensor | Pizzato NS E4ZZ1SQK-F41, NSE4ZZ1SQK-F41V60 |
motor | SEW SA77DRN112M2/LN |
module | GE VersaMax Micro IC200UEX222-C 99%new |
sensor | TURCK FCS-GL1/2A4-NAEX-H1141/A |
sensor | TURCK FMX-IM-3UP63X |
sensor | Labom CE6120-A1059-H1-K1020-T120 |
sensor | Labom CE6120-A1091-H1-K1020-T311 |
sensor | Labom CE6120-B1058-H1-K1020-T311 |
sensor | Labom CE6120-A1058-H1-K1020-T311 |
sensor | Labom CE6120-A1060-H1-K1020-T120 |
sensor | Pepperl Fuchs 20MM,NJ20+U10+E2-Y111572 |
motor | sew R67 DRN100LS4 BE5HR IP65 |
motor | sew RF67 DRN100L4/C IP65 |
motor | sew RF77 DRN112M4/BE5/C IP65 |
motor | Sew R37DR2S63M4/2/FG |
sensor | LARM IRC 320/1000 PB (161170) |
sensor | SICK KTM-LN22181P |
sensor | SICK KTM-LP22182P |
sensor | SICK IME12-04BPPZC0S |
sensor | SICK WTB16P-24161220A00 |
valve | Fairchild 4514AI |
sensor | Leuze LE25C.1/2N-M12 |
sensor | Leuze 50124943 |
sensor | Leuze 50145473 |
sensor | SICK GL10-F4531S09 |
sensor | Leuze LV462B/24-150-M8 |
sensor | BALLUFF BES 516-324-SA-26-05 |
Reducer | Sew SA47/T DRN80MK4/BE1HF |
Reducer | Sew SA67DRN90L4/BE5/TH |
Reducer | Sew R37 DR2S63M4/2 |
valve | SMC ASV410F-03-08S |
heater | Conti-Elektron 5E235AE30B |
encoder | Baumer EIL580-SC10.5FQ.00360.A |
module | PILZ 570610 |
sensor | Norgren QA/8160/W1/00 |
actuator | Auma D-79379 SA14.2.F14 Voltage 3F/400V/50Hz connection: F14 C 250 Nm 22min |
sensor | Omron E3S-DBN21 |
sensor | SMC PS1100-R06L |
Planetary gear box | Bonfiglioli MPD100650015 |
sensor | Klay Instruments 2000-SAn-2-W-H-GC |
gateway | Bihl+Wiedemann ASI-3 PROFIBUS BWU2227 |
valve | Honeywell Z11AS 1/2"A |
fuse | SIBA NH1 200A |
sensor | TURCK BF23S 17237 |
coil | METAL WORK W0911100017 |
sensor | IFM TA2511 |
electrical test pen | FLUKE 1AC-C2-II |
sensor | IFM TA2415 |
switch | Schneider ZCKE05C |
temperature control | Danfoss RT 26 017-518066 |
brake | Sew BMG4 40NM/230AC/96DC 8671931 |
pneumatic pump | Parker SMB60301.45112IDW642 |
pneumatic pump | Parker SMB8245038192IBW642 |
sensor | EMA PA1169 |
brake | Sew Eurodrive BE05A |
frequency converter | sew MXD61B1320-503-4-00 |
switch | Schneider XPSDMB1132P |
switch | Schneider XY2CJS19 |
sensor | Leuze GS 61/6D.2,425-S12 |
sensor | Leuze 50127061 HT46CI/4P-M12 |
sensor | Leuze 50127012 PRK46C/4P-M12 |
sensor | SICK WF120-60B410 6028442 |
belt | MITSUBOSHI S3M 264 ( S3M264 ) 10mm |
sensor | Omron LIMITED SWITCH E2A-S08LS02-WP-D1 Discontinue production to replace E2E-X2D1-N 2M |
sensor | Omron LIMITED SWITCH E2E2-X3D1 Discontinue production to replace E2E-X3D1L 2M OMS |
module | ERHARDT+LEIMER DO2000 |
power supply | Schneider Electric ABLP1A24062 |
sensor | SICK i16-SA203 |
sensor | Omron V430-F000M12M-SRX |
encoder | Hohner Serie H3365W/1000 |
module | LS Electric XEC-DN60SU |
module | LS Electric XBO-TC02A |
module | LS Electric XBL-EMTA |
sensor | SICK LFV200-XXTGACPVL |
button | Schneider Easy XA2 XA2EJ33 |
button | Schneider XB5 XB5AJ21 |
sensor | IFM IE5351 |
sensor | IFM IFT203 |
Liquid level switch | KATU LS280-L030-M |
solenoid valve | Festo CPE24-M1H-5/3 G-3/8 |
sensor | Datalogic S5N-PA-5-C01-PK |
pump | Wilden P1/PPPP/WF/TF/TTV |
valve | Bray 921190-11355532 / 17.S21000546 |
relay | Omron H5CL-AD |
sensor | SICK 1040731 np1803 |
sensor | IFM IIT205 |
sensor | SICK IDM261-411S |
sensor | SICK DFS60E-BEEC00200 |
sensor | Schmersal CSS11-30S-D-M-ST |
filter cartridge | Piab 0128423 |
Conversion switch | CEMA P9MMB4T |
light | HACH LZV565 |
light | HACH A23792 |
light | HACH A23778 |
heat exchanger | Alfa Laval ACH-500DQ-250H-F |
sensor | SICK WTB12-3P2431 |
operation panel | KUKA KCP2 00-110-185 |
connect | Zebra CBA-U21-S07ZBR |