switch |
WTB12-3P2461S58 |
4 |
switch |
i12-SB213 6025059 |
6 |
switch |
WTB12-3P2431 |
5 |
switch |
2P HC+NO M20х1.5 SchE XCKS131H29 |
10 |
switch |
2P HC+NO M20х1.5 SchE XCKS131H29 |
¥260.00 |
switch |
PSEN sl-1.0p 1.1 VA 1switch 570640 |
5 |
switch |
cs3.1n 1switch 541053 |
10 |
switch |
Pilz PNOZ m EF 4DI4DOR 772143 |
1 |
switch |
PSEN cable M12-8sf M12-8sm, 10m 540342 |
10 |
switch |
PNOZ S4 751104 |
3 |
switch |
PSEN sl-1.0p 1.1 1switch 570610 |
2 |
switch |
84-5040.0040 EAO |
2 |
switch |
Eaton NZM4-XHBR, NO.0000271842 |
2 |
switch |
Samson 3730-0 Var-ID 2659921 |
1 |
switch |
Samson 3725 Var-ID 4293138 |
1 |
switch |
EATON T5B-3-8901/I4/SVB3+K-CI-207244 |
2 |
switch |
EATON T5B-4-15682/I4/SVB+K-CI |
2 |
switch |
siemens 3RV2011-4VA15 |
1 |
switch |
Schneider ZB5 AD2 |
20 |
switch |
Schneider ZB5 AD3 |
5 |
switch |
Schneider ZB5 AS844 |
10 |
switch |
Schneider XALK178F |
10 |
switch |
Schneider ZB5 AC2 |
5 |
switch |
Schneider ZB5 AW313 |
5 |
switch |
Schneider ZB5 AW333 |
10 |
switch |
Schneider ZB5 AW343 |
10 |
switch |
Schneider ZB5 AW353 |
5 |
switch |
Schneider ZB5 AZ009 |
50 |
switch |
Schneider XPEM3100D |
1 |
level switch |
MOBREY S36DA/F84 |
1 |
switch |
Schmersal AZM 161-STS30-08 101173763 |
1 |
switch |
Schmersal AZM 161SK-12/12RK -110/230 101166282 |
1 |
switch |
Omron D4B-2511N |
1 |
switch |
siemens 3KA7132-3AA00 |
1 |
switch |
Allen Bradley 800F-NX-BX01 |
30 |
switch |
Kromschroder DG 6U-3 8447250 |
2 |
switch |
ABB 1SDA054441R1 |
2 |
switch |
ABB 1SDA054461R1 |
2 |
switch |
ABB 1SAM550000R1010 |
2 |
switch |
ABB 2CDS252001R0024 |
11 |
switch |
ABB CDS251001R0024 |
4 |
switch |
ABB 2CDS271061R0104 |
9 |
switch |
ABB 2CDS273001R0164 |
1 |
switch |
Eaton NZM2/3-XU208-240AC |
4 |
switch |
Siemens 3RT2026-1AP00 |
5 |
switch |
Siemens 3RT2037-1AK60 |
6 |
switch |
Siemens 3RV2011-0JA20 |
1 |
switch |
Siemens 3RV2917-5AA00 |
2 |
switch |
Schneider Telemecanique XSAV12373 |
5 |
switch |
Schneider ZCMD39 1NO2NC |
5 |
switch |
Schneider ZCMC39L5 1NO2NC |
5 |
switch |
Festo SMEO 1-S-LED-24-B |
2 |
switch |
MTL5541A separator AI 1-kan |
1 |
switch |
ABB 1SAM451000R1015 |
3 |
switch |
ABB 1SAM350000R1011 |
4 |
switch |
Rittal SV 9340.550 OM 32А |
4 |
switch |
Telemecanique 60947-5-1, Ui 60V AC-15 le 4F |
5 |
switch |
ABB 1SBL157001R1310 |
10 |
switch |
ABB 1SBL137001R1310 |
10 |
switch |
Schmersal BNS16-12ZV |
3 |
switch |
Schneider Electric XCMD2116 L3 |
5 |
CAM SWITCH |
BREMAS ERSCE CA06300G4LE3 |
1 |
changeover switch |
BREMAS XNF0164BK6 4P 16A 690V |
1 |
Liquid level switch |
KSR-OPTO.211300000.0660, KSR KUEBLER Stop production and upgrade OLS-2AI |
2 |
Bluetooth switch amplifier |
KSR-OPTO.250.2.4.1 KSR KUEBLER Stop production and upgrade OSA-SCI |
2 |
switch |
Cisco NIM-2GE-CU-SFP |
2 |
switch |
Dungs LGW 3 A4; .221590 |
6 |
switch |
Schneider XCKJ10541H29 |
20 |
switch |
EATON M22-D-R-X0/K11, 216605 |
5 |
switch |
EATON M22-PVT45P, 121462 |
3 |
switch |
EATON M22-L-R 216772 |
2 |
switch |
Schneider ZCKE05C |
26 |
switch |
Schneider XPSDMB1132P |
1 |
switch |
Schneider XY2CJS19 |
2 |
Liquid level switch |
KATU LS280-L030-M |
10 |
Conversion switch |
CEMA P9MMB4T |
10 |
Product Description
Moulded case circuit breaker,AC690V,50/60HZ
Rated current from 12.5A to 1000A
CE Certificate approved
2P,3P,4P all ok
MZ(S)Series Moulded case circuit breaker is mainly suitable for using in the electric Power system AC 50Hz, rated insulated voltage 690V (insulated voltage 400V in the Controlled circuit) and rated operating voltage up to 690V, used for distribution And overload, short circuit and underload protection of circuit and equipment, And also for the infrequent making and breaking circuit under normal conditions.
Detailed Photos
Product Parameters
Rated uninterrupted current(Iu) |
A |
160 |
250 |
250/320/400/630 |
Number of poles |
NO. |
3 4 |
3 4 |
3 4 |
Rated operating voltage(Ue) |
(AC)50/60Hz V |
690 |
690 |
690 |
|
DC V |
500 |
500 |
750 |
Rated impulse withstand voltage |
ka |
8 |
8 |
8 |
Rated insulation voltage |
V |
800 |
800 |
1000 |
Frequency test voltage 1 minute |
V |
3000 |
3000 |
3500 |
Rated ultimate short circuit breaking capacity(Icu) |
|
N |
S |
H |
L |
N |
S |
N |
S |
H |
L |
V |
(AC)50/60Hz 220/230V |
ka |
65 |
85 |
100 |
120 |
50 |
85 |
70 |
85 |
100 |
200 |
200 |
(AC)50/60Hz 380/400V/415V |
ka |
36 |
50 |
70 |
85 |
36 |
50 |
36 |
50 |
70 |
120 |
200 |
(AC)50/60Hz 440V |
ka |
30 |
45 |
55 |
75 |
25 |
40 |
30 |
40 |
65 |
100 |
180 |
(AC)50/60Hz 500V |
ka |
25 |
30 |
36 |
50 |
20 |
30 |
25 |
30 |
50 |
85 |
150 |
(AC)50/60Hz 690V |
ka |
6 |
7 |
8 |
10 |
5 |
8 |
20 |
25 |
40 |
70 |
80 |
(DC) 250V 2P in series |
ka |
36 |
50 |
70 |
85 |
36 |
50 |
36 |
50 |
70 |
100 |
150 |
(DC) 250V 3P in series |
ka |
40 |
55 |
85 |
100 |
40 |
55 |
. |
. |
. |
. |
. |
(DC) 500V 2P in series |
ka |
. |
. |
. |
. |
. |
. |
25 |
36 |
50 |
70 |
100 |
(DC) 500V 3P in series |
ka |
36 |
50 |
70 |
85 |
36 |
50 |
. |
. |
. |
. |
. |
(DC) 750V 3P in series |
ka |
. |
. |
. |
. |
. |
. |
16 |
25 |
36 |
50 |
70 |
Rated short-circuit breaking capacity(Ics) |
|
|
|
|
|
|
|
|
|
|
|
|
(AC)50/60Hz 220/230V |
%Icu |
100% |
100% |
100% |
75% |
75% |
50% |
|
|
|
|
|
(AC)50/60Hz 380/400V/415V |
%Icu |
100% |
100% |
100% |
75%(70ka) |
75% |
50%(24ka) |
|
|
|
|
|
(AC)50/60Hz 440V |
%Icu |
100% |
100% |
100% |
75% |
75% |
50% |
|
|
|
|
|
(AC)50/60Hz 500V |
%Icu |
100% |
100% |
100% |
75% |
75% |
50% |
|
|
|
|
|
(AC)50/60Hz 690V |
%Icu |
100% |
100% |
100% |
75% |
75% |
50% |
|
|
|
|
|
Rated short-circuit breaking capacity(Icm) |
|
|
|
|
|
|
|
|
|
|
|
|
(AC)50/60Hz 220/230V |
ka |
143 |
187 |
220 |
264 |
|
|
|
|
|
|
|
(AC)50/60Hz 380/400V/415V |
ka |
75.6 |
105 |
154 |
187 |
|
|
|
|
|
|
|
(AC)50/60Hz 440V |
ka |
63 |
91.5 |
121 |
165 |
|
|
|
|
|
|
|
(AC)50/60Hz 500V |
ka |
52.5 |
63 |
75.6 |
105 |
|
|
|
|
|
|
|
(AC)50/60Hz 690V |
ka |
9.2 |
11.9 |
13.6 |
17 |
|
|
|
|
|
|
|
Opening time(415V) |
ms |
3 |
3 |
3 |
3 |
|
|
|
|
|
|
|
Use of times(415V) |
|
A |
|
|
|
|
|
|
|
|
|
|
Reference Standard |
|
IEC 60947-2 |
|
|
|
|
|
|
|
|
|
|
Isolation |
|
. |
|
|
|
|
|
|
|
|
|
|
Release,Thermal-magnetic |
|
|
|
|
|
|
|
|
|
|
|
|
T is not Adjustable,M is not adjustable |
TMF |
. |
|
|
|
|
|
|
|
|
|
|
T is not Adjustable,M is not adjustable |
TMD |
. |
|
|
|
|
|
|
|
|
|
|
T adjustable,M adjustable (5..10*ln) |
TMA |
. |
|
|
|
|
|
|
|
|
|
|
T adjustable,M adjustable (3*ln) |
TMG |
. |
|
|
|
|
|
|
|
|
|
|
T adjustable,M adjustable (2.5…5*ln) |
TMG |
. |
|
|
|
|
|
|
|
|
|
|
Electromagnetic |
PR221DS |
.(MF up to In 12.5A) |
|
|
|
|
|
|
|
|
|
|
|
PR221GP/PR221MP |
. |
|
|
|
|
|
|
|
|
|
|
|
PR222DS |
. |
|
|
|
|
|
|
|
|
|
|
|
PR223DS |
. |
|
|
|
|
|
|
|
|
|
|
|
PR231/P |
. |
|
|
|
|
|
|
|
|
|
|
|
PR232/P |
. |
|
|
|
|
|
|
|
|
|
|
|
PR331/P |
. |
|
|
|
|
|
|
|
|
|
|
|
PR332/P |
. |
|
|
|
|
|
|
|
|
|
|
Interchangeability |
|
. |
|
|
|
|
|
|
|
|
|
|
Type |
|
F-P |
|
|
|
|
|
|
|
|
|
|
Terminal Type |
Fixed |
F-FC Cu-FC CuAl-EF-ES-R |
|
|
|
|
|
|
|
|
|
|
|
Plug-in |
F-FC Cu-FC CuAl-EF-ES-R |
|
|
|
|
|
|
|
|
|
|
|
Out of style |
. |
|
|
|
|
|
|
|
|
|
|
On the DIN rail |
|
|
|
|
|
|
|
|
|
|
|
|
Mechanical life |
Operating cycles |
|
25000 |
|
|
|
|
|
|
|
|
|
|
Operating cycles per hour |
|
240 |
|
|
|
|
|
|
|
|
|
Electrical life |
Operating cycles |
|
8000 |
|
|
|
|
|
|
|
|
|
|
Operating cycles per hour |
|
120 |
|
|
|
|
|
|
|
|
|
Basic dimensions- fixed 3pole |
3pole |
W/L(mm) |
90 |
|
|
|
|
|
|
|
|
|
|
|
W/L(mm) |
120 |
|
|
|
|
|
|
|
|
|
|
4 pole |
D(mm) |
70 |
|
|
|
|
|
|
|
|
|
|
|
H(mm) |
130 |
|
|
|
|
|
|
|
|
|
Weight |
Fixed |
3/4 pole(kg) |
1.1/1.5 |
|
|
|
|
|
|
|
|
|
|
Plug-in |
3/4 pole(kg) |
1.5/1.9 |
|
|
|
|
|
|
|
|
|
|
Out of style |
3/4 pole(kg) |
. |
|
|
|
|
|
|
|
|
|