1.Brief Introduction
XGN15-12(L)/T630-25 0r XGN15-12(L . R)/T100-31.5 Cubicle fixed AC metal enclosed switchgear is mainly used for looped network power supply or biradial power supply of electric power system with 3-phase ,AC 50Hz and rated voltage 10KV. It also can be used for terminal power supply as the control device of electric energy and protection device of utilization equipment. More over, it also can be suitable for this switchgear4.The main technical parameters
NO. | Item | Unit | Technical parameters | ||||
XGN15-12(F) | XGN15-12(F,R) | ||||||
1 | Rated voltage | KV | 12 | ||||
2 | Rated Frequency | Hz | 50 | ||||
3 |
Rated insulation level | 1 min power frequency withstand voltage | Kv | To-Grounding and phase -to-phase42;Isolating distance48 | |||
Lighting impulse withstand voltage(peak) | kv | To-Ground and phase-to-phase 75; Isolating distance85 |
|||||
4 | Rated current of main bus | A | 630 | ||||
6 | Rated current | A | 630 | 125 | |||
7 | Rated closed loop breaking current | A | 630 | ||||
8 | Rated charging breaking current | A | 10 | ||||
9 | Rated transfer current | A | 1700 | ||||
10 | Breaking no-load transformer capacity | KVA | 1600 | ||||
11 | Rated making current(peak) | KA | 63 | ||||
12 | Rated short-time withstand current | KA | 25 | ||||
13 | Rated peak withstand current | KA | 63 | ||||
14 | Rated short-circuit breaking current | KA | |||||
15 | Peak withstand current of ground circuit(prospective) | KA | 63 | 31.3(Prospective) | |||
16 | Short-time withstand current of grounding circuit | KA | 25 | ||||
17 | Fuse model | SLAJ | |||||
18 | Rated voltage of auxiliary circuit | V | DC220 110 AC220 110 | ||||
19 | IP Code | IP3X | |||||
20 |
Mechanical life |
Load switch (times) | Times | 5000 | |||
Earthing switch(times) | Times | 2000 |
Name | Description | Unit | |
Load break switch | FL+C2:D7+C2:D12N36- 24/630-20 | Load break switch for Two positions, no earthing with Gas-pressure meter |
Set |
FL(R)N36- 12D/630-20 | Load break switch for Three positions with Gas-pressure meter |
Set | |
FLN36- 24/630-20 | Load break switch for Two positions, no earthing with Gas-pressure meter |
Set | |
FL(R)N36- 24D/630-20 | Load break switch for Three positions with Gas-pressure meter |
Set | |
FL(R)N36- 35/630-20 | Load break switch for Two positions, no earthing with Gas-pressure meter |
Set | |
FL(R)N36- 35D/630-20 | Load break switch for Three positions with Gas-pressure meter |
Set | |
Operating mechanism | Organization for in line | Manual operation for K type(No button) (not suitable for fuses) | Set |
Organization for in and out line | Manual operation for A type(with button) | Set | |
Organization for in and out line | Electric operation AC220V | Set | |
Organization for in line | Manual for closing and electric for Opening | Set | |
Only for 12kv 24kv (outgoing line) 35kv load break switch is protected by microcomputer |
Fuse holders |
Top and bottom fuse holder 6pcs totally | Set |
Fuse | (See the below) | Set | |
Interlock system | Down door interlock | The interlock for down door |
Set |
Trip device(Including the trip system and trip interlock,work together with fuse holders) |
Trip system |
Set | |
Trip interlock | Set | ||
Earthing interlock |
500 #/375# earthing components | Set | |
Sensors | 3pcs as one set | Set | |
Voltage Indicator | L-6 | Set |
Transformer capacity (kVA) |
100 | 125 | 160 | 200 | 250 | 300 315 |
400 | 500 | 630 | 750 800 |
1000 | 1250 | |
Rated current of fuse element (A) | 16 | 20 | 25 | 31.5 | 40 | 50 | 63 | 80 | 100 |
SF6 (SM6) Switchgear cabinet types | ||||||||||
NO. | Name | Specification | Unit | Qty | NO. | Name | Specification | Unit | Qty | |
XGN15-12 Lifttlig Switchgear | Set | 1 | XGN15-12 Outline Switchgear | Set | 1 | |||||
1 | Lighting Arrester | HY5WS 17/50 | Set | 1 | 1 | SF6 load break swith | FRLN36-12D/125-31.5 | Set | 1 | |
2 | Voltage display | L-6 | Set | 1 | 2 | Operating mechanism | Manual for closing and Electric for Open |
|||
3 | Electromagnetic lock | DSN-Y | Set | 1 | 3 | Gas meter | Set | 1 | ||
4 | Sheet metal | 375*916*1635 | Set | 1 | 4 | Outline Electromagnetic lock | 375# | Set | 1 | |
5 | Lighting Arrester | HY5WS 17/50 | Set | 1 | ||||||
NO. | Name | Specification | Unit | Qty | 6 | Sensor | CG5-10 140mm | Set | 1 | |
XGN15-12 Mertering Switchgear | Set | 1 | 7 | Voltage display | L-6 | Set | 1 | |||
1 | Sensor | CG5-10 140mm | Set | 1 | 8 | Fuse | 10A-63A | Set | 1 | |
2 | Voltage display | DXN-Q | Set | 1 | 9 | Sheet metal | 375*1000*1635 | Set | 1 | |
3 | Electromagnetic lock | DSN-Z 220V | Set | 1 | ||||||
4 | Sheet metal | 750*916*1635 | Set | 1 | NO. | Name | Specification | Unit | Qty | |
XGN15-12 Outline Switchgear | Set | 1 | ||||||||
NO. | Name | Specification | Unit | Qty | 1 | SF6 load break swith | FRLN36-12D/125-31.5 | Set | 1 | |
XGN15-12 Inline Switchgear | Set | 1 | 2 | Operating mechanism | Electric AC2200 | Set | 1 | |||
1 | SF6 load break swith | FLN36-12/620-20 | Set | 1 | 3 | Gas meter | Set | 1 | ||
2 | Operating mechanism | Manual A type | Set | 1 | 4 | Outline Electromagnetic lock | 375# | Set | 1 | |
3 | Gas meter | Set | 1 | 5 | Lighting Arrester | HY5WS 17/50 | Set | 1 | ||
4 | Interlock for up and down door | Set | 1 | 6 | Sensor | CG5-10 140mm | Set | 1 | ||
5 | Lighting Arrester | HY5WS 17/50 | Set | 1 | 7 | Voltage display | L-6 | Set | 1 | |
6 | Sensor | CG5-10 140mm | Set | 1 | 8 | Fuse | 10A-63A | Set | 1 | |
7 | Voltage display | DXN-Q | Set | 1 | 9 | Sheet metal | 375*1000*1635 | Set | 1 | |
8 | Electromagnetic lock | DSN-Z 220V | Set | 1 | ||||||
9 | Sheet metal | 375*916*1635 | Set | 1 | NO. | Name | Specification | Unit | Qty | |
XGN15-12 Inline VCB switchgear | Set | 1 | ||||||||
NO. | Name | Specification | Unit | Qty | 1 | VCB | VS1-12/630A-25KA | Set | 1 | |
XGN15-12 Inline Switchgear | Set | 1 | 2 | Disconecting switch | GN30-12/630-25KA | Set | 1 | |||
1 | SF6 load break swith | FLN36-12/620-20 | Set | 1 | 3 | Metal plate mechanism | Set | 1 | ||
2 | Operating mechanism | Electric AC2200 | Set | 1 | 4 | Lighting Arrester | HY5WS 17/50 | Set | 1 | |
3 | Gas meter | Set | 1 | 5 | Sensor | CG5-10 140mm | Set | 1 | ||
4 | Interlock for up and down door | Set | 1 | 6 | Voltage display | DXN-Q | Set | 1 | ||
5 | Lighting Arrester | HY5WS 17/50 | Set | 1 | 7 | Electromagnetic lock | DSN-Z 220V | Set | 1 | |
6 | Sensor | CG5-10 140mm | Set | 1 | 8 | Sheet metal | 750*916*1885 | Set | 1 | |
7 | Voltage display | DXN-Q | Set | 1 | ||||||
8 | Electromagnetic lock | DSN-Z 220V | Set | 1 | NO. | Name | Specification | Unit | Qty | |
9 | Sheet metal | 375*916*1635 | Set | 1 | XGN17-12 Outline VCB switchgear | Set | 1 | |||
1 | VCB | VS1-24/630A-25KA | Set | 1 | ||||||
NO. | Name | Specification | Unit | Qty | 2 | Disconecting switch | GN30-10/630-25KA | Set | 1 | |
XGN15-12 Outline Switchgear | Set | 1 | 3 | Metal plate mechanism | Set | 1 | ||||
1 | SF6 load break swith | FRLN36-12D/125-31.5 | Set | 1 | 4 | Lighting Arrester | HY5WS 17/50 | Set | 1 | |
2 | Operating mechanism | Manual A type | Set | 1 | 5 | Sensor | CG5-10 140mm | Set | 1 | |
3 | Gas meter | Set | 1 | 6 | Voltage display | DXN-T | Set | 1 | ||
4 | Outline Electromagnetic lock | 375# | Set | 1 | 7 | Sheet metal | 1000*1210*2300 | Set | 1 | |
5 | Lighting Arrester | HY5WS 17/50 | Set | 1 | 8 | Grounding knife | JN15-12 | Set | 1 | |
6 | Sensor | CG5-10 140mm | Set | 1 | ||||||
7 | Voltage display | L-6 | Set | 1 | Note; | This price without Copper bar,without current transformer,without seal plate. | ||||
8 | Fuse | 10A-63A | Set | 1 | extra add 20 usd ,if the Sheet metal need higher one floor or wider one floor | |||||
9 | Sheet metal | 375*1000*1635 | Set | 1 |
7.The product photo for the SF6 (SM6) switchgear cabinet photo